Parker sporlan s virtual engineer is an innovative design tool for climate control and refrigeration applications. For over 80 years the parker sporlan division has set the industry standard for the development and manufacture of leading edge high quality hvacr components. Sporlan valve company offers over 20 types of thermo expansion valves designed for application no matter when, where, or what the hvac situation is. Thermostatic expansion valves flare and solder connections thermostatic expansion valve replacement parts item number part number and description drawings on pages 4 thru 11 valve type and quantity of part required per valve r sr er rc f ef bf ebf sbf g eg c s ebs p small o large o 183019 772000 inlet strainer 14 sae 1 183015 3008000 1 1. Do not use this item for any installation or repair of potable water applications. This product does not comply with the safe drinking water act, which requires that products meet lowlead standards in order to be used in systems providing water for human consumption drinking or cooking. Sporlan attempts to provide the best possible service to all clients.
They regulate refrigerant flow by maintaining a nearly constant superheat at the evaporator outlet. Thermostatic expansion valves sporlan thermostatic expansion valve capacities for r12, r4a, r401a, r409a tons of refrigeration air conditioning, heat pump and commercial refrigeration applications valve types nominal capacity refrigerant 12 4a 401a 409a recommended thermostatic charges fc, fcp60 jc, jcp60 xc, xcp60 fc, fcp60. Sporlan thermostatic expansion valves for use on refrigeration andor air conditioning systems only bulletin 1010, april 2011 supersedes bulletin. The following procedure should be used when selecting a. Aug 24, 2018 sporlan valve product selection program is used by 2 users of software informer. A discussion of the relationship between valve capacities and superheat settings can be found in bulletin 109. For use on refrigeration andor air conditioning systems only bulletin 2010, november 1999 supersedes bulletin 2010, june 1975 and all prior publications. Unfollow sporlan expansion valve to stop getting updates on your ebay feed. Turn the adjusting stem counter clockwise in increments. The ratings for evaporator temperatures 40f, 20f, 10f. The tseries takeapart valves, with adjustable superheat and replaceable, interchangeable components are ideal for original equipment and field replacements in air. Sporlan type rc valve is a small brass body, externally adjustable valve with balanced port construction.
The most popular version of this product among our users is 5. Sep 22, 2015 in this video i go over sporlan txv selection for refrigeration applications. Sporlan electric expansion valves rsdtotal control. Welcome to parker sporlan s virtual engineer sizing and selection tool parker sporlan s virtual engineer is an innovative design tool for climate control and refrigeration applications. Welcome to parker sporlan s virtual engineer sizing and selection tool. This sporlan expansion valve is known to provide optimum performance for air conditioners and various refrigerating equipment. Txv selection how do i select a txv for a particular application. Selecting the cartridge see table on previous page. Sporlan distributors can be used for the above applications if used with a sporlan auxiliary side connector asc. The ex4ex8 are stepper motor driven valves that are optimized for the control of liquid or gaseous mass flow in refrigeration systems multifunction capability as expansion valve, hot gas bypass, suction gas throttling, head pressure, liquid line actuator and other applications systems. Identifying sporlan thermostatic expansion valves to.
Refer to bulletin 1011 for a complete discussion on installing and servicing thermostatic expansion valves. The rc valves are available for replacement of types cbi and cbbi valves. Thermostatic expansion valve selection when selecting a thermostatic expansion valve tev for use with a sporlan type distributor, an externally equal. Pressure equalizing flare hc14fw rcd12fw nif14 ff14 gf14 df14 ra14fa.
The following is a selection of sporlan references available for download. In this video i go over sporlan txv selection for refrigeration applications. The sporlan thermo expansion valve txv is primarily designed to regulate the refrigerant liquid flow. If you would like to receive pricing andor paper copies of literature, please contact your sales office or contact sporlan division by phone at 636 2391111. The sporlan txv balances the liquid evaporation into the refrigerant gas. My coworkers there were fun and nice to get along with, very sociable. Sporlan has also made a point to provide consumers with a variety of maintenance options. Expansion valve cross reference thermostatic expansion valve cross reference interchangeable orifice nominal capacity tons connection alco sporlan parker virginia singer danfoss totaline replacement type orifice pn pn body orifice conn.
January 1998 bulletin 1010 thermostatic expansion valves. The thermostatic expansion valve tev controls the flow of liquid refrigerant. Use a separate discharge bypass valve for each evaporator section. Use one discharge bypass valve to feed two bypass lines, each with a check valve between the bypass valve and the evaporator section inlet. Sporlan expansion valve software free download sporlan. Determine the liquid temperature of the refrigerant entering the valve the tev. Sporlan valve product selection program is used by 2 users of software informer. Parker sporlan s new webbased product selection program, virtual engineer, allows the user to size, select and fully configure products for air conditioning and refrigeration applications. For full access to courses youll need to take a minute to create a new account for yourself on this web site. Sporlan selection program for hvacr applications is new virtual. Sporlan thermostatic expansion valve refrigeration and. If actual conditions differ from those above, valve selections should be made from sporlan bulletins 1010 and 2010. Certain design characteristics may indicate or restrict application to certain system conditions, but the fundamental operation of a sporlan electric valve is consistent.
The check valves will prevent interaction between thetevs when the bypass valve is closed. Sporlan thermostatic expansion valves for use on refrigeration andor air conditioning systems only bulletin 1010, april 2011 supersedes bulletin 1010, october 2009 and all prior publications. For over 85 years the parker sporlan division has set the industry standard for the development and manufacture of leading. Buy sporlan expansion valve and sporlan thermostatic valves. In order to make an accurate thermostatic expansion valve txv selection, it is necessary to match the flow rate in tons of the txv to the tonnage rating of the evaporator coil. Order from heritage parts the leading online provider of oem commercial kitchen replacement parts. In the below example we will compare a thermostatic expansion valve with an electric expansion valve. Select a valve based on the design evaporating temperature. While it is without a doubt one of the most commonly used products in the sporlan line, it is often one of the least understood. Sporlan valve product selection program download free.
Thermostatic expansion valve sporlan type w parker na. Externally equalized valves are used with coils having refrigerant distributors. Sporlan valve company ean 0696498777298, 0687472030577. Identifying sporlan thermostatic expansion valves bulletin 122 page 15 for applications with an external equalizer use kit number kt1b. Count the total number of turns front seat to back seat, then front seat the adjustment stem to 50% of the total turns counted. The emerson nxt series is a balanced ported valve designed for high efficiency r410a air conditioning and heat pump applications. Sporlan thermostatic expansion valves gps information. Sporlan thermal expansion valves txvs are available in a variety of heat pumps, air conditioning, and refrigeration applications. Sporlan type v thermostatic expansion valves are designed for use on air conditioning and refrigeration units. The r22 nominal tonnage is used as a reference except as noted. Equally important is the proper installation, which can determine the. Sporlan type w thermostatic expansion valves are designed for use on air conditioning and refrigeration units. Equally important is the proper installation, which can determine the success or failure of the entire system.
Sporlan valve product selection program download free version. The type re valve is a small balanced port valve designed for use on refrigeration. Unfollow sporlan expansion valve 5 ton to stop getting updates on your ebay feed. Sporlan type o thermostatic expansion valves are designed for use on air conditioning and refrigeration units. With such a large emphasis on quality, consumers love to buy sporlan expansion valve. Sei electric expansion valves selection procedure sporlan electric expansion valves the electric expansion valve eev controls the flow of refrigerant entering the direct gain due to the vertical lift drop of the liquid line. Parkers virtual engineer to replace sporlan selection program. Each of the individual courses may also have a one. Determine the liquid temperature of the refrigerant entering the valve. Welcome to parker sporlans virtual engineer sizing and selection tool parker sporlans virtual engineer is an innovative design tool for climate control and refrigeration applications. You can check current program updater, kruger selection program, sporlan valve unit.
Certain design characteristics may indicate or restrict application to certain system conditions, but the fundamental operation of. See bulletins 109 and 1010 for complete application information. Thermostatic expansion valve sporlan type o parker na. The thermostatic expansion valve is the most extensively used type of metering device in refrigeration and air conditioning. From the 1947 launch of the catchall, the worlds first molded core filterdrier, to todays intricate electronic valve and controller packages, for over 80 years sporlan has set the industry standard for the development and manufacture of leading edge hvacr components. Sporlan txv valve sporlan thermal expansion valve sporlan. The hardest part of the job was just learning some of it in the beginning and remembering what to do sometimes. These valves contain internal check valves to allow reverse flow on heat pump applications. This sporlan expansion valve makes use of the huge and flat stainless steel film and the design of needle valve base, making needle valve match correctly with valve port and keeping good tightness between them. After making your selections, you can create a pdf report rpt field containing all of your inputs, valve selection, and calculated values or export the values in an excel file. Adjust the superheat setting on the expansion valve duration.
I was a packer at sporlan valve, i packed, bagged, counted, and boxed up coolant valves all day. Refrigeration expansion valve animated explanation. A sporlan refrigerant distributor for most requirements thoroughly engineered, continually improved and laboratory and field tested for over 50 years. Each of the individual courses may also have a onetime enrolment key, which you wont need until later. Virtual engineer features quick selection of single or multiple components by template. Here you can find a thermostatic expansion valve for nearly any hvac job. An innovative dashboard and project system make saving, editing, and sharing projects easy. Sporlan selection program for hvacr applications is new. The factory setting of a sporlan tev is close to center stem. Sporlan expansion valve, free sporlan expansion valve software downloads. On multiple evaporator systems, select each valve on the basis of individual evaporator capacity. Sporlan refrigeration troubleshooting app is designed to assist field technicians of all skill levels with troubleshooting components of a direct expansion dx refrigeration system.
1318 1589 1428 1118 424 151 1016 1180 287 174 1333 1101 404 578 33 1591 954 1137 418 1576 640 1141 392 1461 1581 356 496 145 1060 620 98 857 776 219 123 401